Sign In | Join Free | My ecer.jp
China Hefei Coolnet power  Co., ltd logo
Hefei Coolnet power Co., ltd
Hefei Coolnet power Co., ltd
Verified Supplier

6 Years

Home > Precision Air Conditioning Units >

Small Enthalpy Difference PAC For Control Environment Changes

Hefei Coolnet power Co., ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Small Enthalpy Difference PAC For Control Environment Changes

Brand Name : Coolent

Model Number : CYAT50-85

Certification : ISO/CE

Place of Origin : China

MOQ : 1

Price : to be Negotiated

Payment Terms : T/T

Supply Ability : 1000/Month

Delivery Time : 4W

Packaging Details : WOODEN

Capacity : 50-90KW

Mounting : Floor Standing

Product Condition : Brand New

Type : Air cooled unit/Water cooled unit/iFree-cooling

Extra Service : Engineers available to service machinery overseas

Voltage : 380/400 VAC,230 VAC,220V

Warranty : 1 Year

Name : PAC systems(Precision Air Cooling Systems)

Refrigerant : R22(R407C/R410A)

Application : Computer Room/Printing factory/Kindergarten,Industrial,Heat recovery,adjust cold/heat/humidity

Color : Black|Grey|White|Other colors

Power : 3N-380V-50Hz,220v/50hz/60hz

Airflow : >15500 m3/h

Function : Cooling Ventilation/Heat Dissipation

Contact Now

Small Enthalpy Difference PAC For Various Application To Control Environment Changes

Product Introduction

Coolnet precision air conditioners are mainly designed to meet the requirements of special craftsmanship and specific environments of precision equipment. Its purpose is to accurately control its temperature, humidity, etc. and require it to be controlled within a certain range. It is also called a constant temperature and humidity air conditioner, which is characterized by having a large air volume and adapting to various changes in thermal load. And coolnet precision air conditioner can control the temperature difference range to 0.1 degrees Celsius or even higher. Similarly, this series of precision air conditioners can use a larger circulating air volume to reduce the enthalpy difference under a certain cooling capacity, so usually the unit can only operate under a relatively high sensible heat ratio. This is precisely suitable for server rooms and data centers which are placed in plenty of equipments with high demand in heat dissipation.

Benefits

Small Enthalpy Difference PAC For Control Environment Changes

Small Enthalpy Difference PAC For Control Environment Changes

Air Supply Method

Small Enthalpy Difference PAC For Control Environment Changes

Applications

Small Enthalpy Difference PAC For Control Environment Changes
  • IDC, Computer room
  • Network equipment room, Server room,communication equipment room
  • Monitoring room, Power distribution room and battery room
  • High precision lab, Test room, Inspection room, Measuring room
  • Industrial control room, High precision workshop

Features

Small Enthalpy Difference PAC For Control Environment Changes
  • The same external pressure requirement. The inner fan can be operated with stepless speed regulation, and the temperature difference between the supply and return air, the temperature of the return air and the temperature of the outlet air can be selected for control.
  • Standard EEV dual electronic expansion valve, low-load dehumidification
  • Large area V-shaped evaporator, high air volume, high sensible heat ratio
  • Large humidification capacity, suitable for poor water quality, low maintenance
  • Frequency conversion series units are equipped with oil separator as standard
  • The power consumption per 1kg/h of humidification should not exceed 0.8kW to achieve energy-saving operation.

Technical Parameters

Model: CYA S20D/U S23D/U S26D/U S28D/U S31D/U S35D/U S40D/U S45D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity KW 20.5 23.5 26.8 28.3 31.5 35.5 40.2 45.6
Sensible KW 18.9 21.6 24.2 26.1 28.9 33.2 37.6 42.2
AEER w/w 3.7 3.6 3.6 3.7 3.7 3.7 3.7 3.6
Air Flow m3/h 6830 7650 7580 8500 9200 9800 10600 12000
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 1 1 1 1 1 1 1 1
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 1 1 1 1 1 1 2 2
Rated current A 2.5 2.5 2.8 3.2 3.5 4.1 4.4 4.9
Rated power W 1050 1100 1200 1300 1320 2000 2150 2400
Reheat Capacity KW 6 6 6 6 9 9 9 9
Reheat Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 5 5 5 13
Rated Current A 6 6 6 6 6 6 6 15
Condensor Model 58 58 80 80 100 120 150 150

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model 2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

Certificates

Small Enthalpy Difference PAC For Control Environment Changes

Factory Details

Small Enthalpy Difference PAC For Control Environment Changes

Packing & Delivery

Small Enthalpy Difference PAC For Control Environment Changes

Case

Small Enthalpy Difference PAC For Control Environment Changes


Product Tags:

Floor Standing PAC System

      

15500 M3/H Precision Air Conditioning Units

      

90KW PAC Units

      
Quality Small Enthalpy Difference PAC For Control Environment Changes wholesale

Small Enthalpy Difference PAC For Control Environment Changes Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Hefei Coolnet power Co., ltd
*Subject:
*Message:
Characters Remaining: (0/3000)